A comprehensive protocol and procedural considerations designed to evaluate the shedding of particles from drug eluting stents
Abstract
The American Society for Testing and Materials (ASTM) [35] and Association for the Advancement of Medical Instrumentation (AAMI)/ International Organization for Standardization (ISO) [36] committees have drafted or passed standards [38, 39] to address the release of particulates into the vasculature by drug eluting stents during deployment and implantation. A new AAMI committee [37] addresses these issues for all implantable medical products. This paper focuses on the concerns of these committees as well as those of stent manufacturers and academicians. A comprehensive approach to the experimental evaluation of particle shedding includes considerations that address equipment choice, system sterilization, test frequency, monitoring of stent deflection, establishment of baseline or background levels of particulates before stent deployment, deployment mechanisms into mock vessels, system hydrodynamics including overall impedance, calibration of all systems including laser counters, filtration of shed particles, and approaches to data analysis. One of the most important decisions that an investigator must make is how often the sampling is done for particulate shedding. In general, there are three temporally linked approaches. The first is simplest and yet the least informative with respect to the time course of shedding. In this case, a sample is taken from the bulk solution at the end of the acute or chronic (durability) test. The second involves the sequential sampling of the bulk solution throughout the test. The last and most informative approach is a continuous monitoring approach. This paper will focus on each step in the generation of the protocol and give pros and cons to each option. Throughout this paper, data from an actual experiment will be presented.
Department(s)
Physics, Astronomy, and Materials Science
Document Type
Article
DOI
https://doi.org/10.1361/cp2007mpmd094
Publication Date
9-23-2007
Recommended Citation
Conti, J., E. Strope, R. Ramesh, C. Conti, and A. Watkins. "A Comprehensive Protocol and Procedural Considerations Designed to Evaluate the Shedding of Particles from Drug Eluting Stents." In Medical Device Materials IV: Proceedings of the Materials & Processes for Medical Devices Conference 2007, September 23-27, 2007, Palm Desert, California, USA, p. 94. ASM International, 2008.
Journal Title
Medical Device Materials IV: Proceedings of the Materials & Processes for Medical Devices Conference